9
IF ...
THEN ...
a rack extension (width)
is not
used
proceed with the next step.
a rack extension (width)
is used
mount the special fiber guides (see chapter 3,
section
“Mounting of special fiber guides”
) and omit the next two steps.
.................................................................................................................................................................................................
10
Mount one DC1001517 fiber guide (item 8) on the top left side of the subrack and one
DC1001516 fiber guide (item 9) on the top right side of the subrack using two M2.5
self-tapping screws.
.................................................................................................................................................................................................
11
Mount one side guide (DC1001518, item 3) at each corner of the subrack by clicking
them into the holes at the top and bottom sides of the subrack.
Mixed configuration:
LambdaUnite
®
MSS and
Metropolis
®
ADM
Mounting the
LambdaUnite
®
MSS subrack
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
D-11
E
N D
O F
S
T E P S
.................................................................................................................................................................................................