Result:
The SCN IP addresses of NE-D and NE-B will appear in the
Selected
Nodes
list.
.................................................................................................................................................................................................
19
Click
OK
.
Result:
The
Explicit Routing Node List Selection Dialog
disappears. The
Path 2
field is populated with the SCN IP addresses of NE-D and NE-B.
.................................................................................................................................................................................................
20
Click
OK
.
Result:
The
Create New Path
screen disappears and the Network Map will display
the configured paths. The first path is highlighted in green, the second (protection)
path in orange.
.................................................................................................................................................................................................
21
Start a signal transmission via both analyzers.
.................................................................................................................................................................................................
22
Check that no bit errors are present.
Test procedure
Proceed as follows to perform the test:
.................................................................................................................................................................................................
1
Remove the fiber connection between NE-C and NE-D.
Result:
The first path between NE-A, NE-B, NE-D and NE-C is highlighted in red,
the second path between NE-A, NE-D, NE-B and NE-C in green.
.................................................................................................................................................................................................
2
Check that no bit errors are present.