STM-1e cable assembly instructions
.................................................................................................................................................................................................................................
Description
There are the following type of connectors:
•
IMS — type 3320.52.1420.0D5 (45°)
•
IMS — type 2630.52.1310.0D5 (straight)
IMS
Important!
Use of the correct tools to ensure a proper connection.
.................................................................................................................................................................................................
1
Strip the cable according to the dimensions indicated in the next figure and tin the
center conductor.
Important!
The stripping lengths depend on the are connector type!
.................................................................................................................................................................................................
2
Pull the crimp outer ferrule over the stripped cable.
.................................................................................................................................................................................................
3
Pull back the cable braid.
.................................................................................................................................................................................................
4
Push the center conductor and the dielectric into the connector housing until the
dielectric stops.
.................................................................................................................................................................................................
5
Solder the inner conductor to the center contact of the connector housing.
.................................................................................................................................................................................................
6
After soldering press the cover into the connector body.
.................................................................................................................................................................................................
7
First roll the cable braid over the termination part (inner ferrule) of the connector and
pull the crimp outer ferrule over that braid.
.................................................................................................................................................................................................
8
Crimp the outer ferrule with a Hexagon Die 4.6 — AGK 3068 by using the Crimp
Tool — AGK 2365.
System cabling and final assembly
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
4-47