Test setup
The following figure illustrates a possible test setup. The number and type of optical
interfaces depends on the customer configuration.
Procedure
Proceed as follows to perform the port transmission test:
.................................................................................................................................................................................................
1
Establish a test setup as shown above.
NOTE:
The analyzer should be connected to a port with the lowest optical port rate
(excluding the GE1SX/4, this might be 2.5G).
.................................................................................................................................................................................................
2
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Cross-Connection
→
Create
to set up the first cross-connection.
Result:
The
Create New Cross Connection
window appears.
.................................................................................................................................................................................................
3
Select/Activate the
Signal Rate Auto Set
check box and define the cross-connection
rate in the
Rate
drop-down list box according to the analyzer signal used. The
following values are possible:
•
VC-3
(SDH) /
STS-1
(SONET)
•
VC-4
(SDH) /
STS-3
(SONET)
•
VC-4-4c
(SDH) /
STS-12
(SONET)
•
VC-4-16c
(SDH) /
STS-48
(SONET)
•
VC-4-64c
(SDH) /
STS-192
(SONET)
Figure 8-4 Daisy chain test
LambdaUnite
NE
SDH/SONET
analyzer
WaveStar CIT
®
STM-x/OC-x
User
panel
OP = Optical Pack
Tx
Rx
Tx
Rx
Tx
Rx Tx
Rx
OP
OP
OP
OP
OP
Tx
Rx
Optical loops
Stand-alone test procedures
Optical port transmission test (daisy chain test)
.................................................................................................................................................................................................................................
8-32
Lucent Technologies - Proprietary
See notice on first page
365-374-187