Proceed as follows to check the “Major” alarm reporting:
.................................................................................................................................................................................................
1
Remove the “Station clock input” cable (external clock source) from the IN port.
.................................................................................................................................................................................................
2
In the
WaveStar
®
CIT
System View
, select
Fault
→
NE Alarm List...
or
Reports
→
NE Alarm List...
to check if the “Timing Reference Failure” alarm is reported to the
WaveStar
®
CIT. Check also the correct behavior on the User Panel (“MJ” LED is
illuminated) and on the rack alarm lamps (“Major” LEDs are illuminated).
.................................................................................................................................................................................................
3
Reconnect the external clock source.
.................................................................................................................................................................................................
4
Check the
WaveStar
®
CIT alarm list for correct clearing of the reported alarm. To
make sure that the “NE Alarm List” reflects the current alarm status, click the
Refresh
button. Furthermore, the “MJ” LED on the User Panel and the “Major” LED at the
rack top should be extinguished.
E
N D
O F
S
T E P S
........................................................................................................................................................................................................................
Stand-alone test procedures
Alarm reporting tests
.................................................................................................................................................................................................................................
8-6
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005