Type a 9-digit number for the cross-connection in the
XC Number
field or use the
automatically generated one.
.................................................................................................................................................................................................
13
Click the
Apply
button to apply your settings and confirm the resulting message by
clicking
Yes
.
.................................................................................................................................................................................................
14
Click
Close
to exit the
Create New Cross Connection
window.
.................................................................................................................................................................................................
15
Verify that the cross-connection is established. Proceed as follows:
1. In the
WaveStar
®
CIT
System View
, select
View
→
Cross-Connections...
2. Select
Shelf 1 (DUR)
of the
Ptn Grp
tab
3. Click
Select
and confirm the resulting message by clicking
Yes
.
.................................................................................................................................................................................................
16
Click
Close
to exit the
View Cross Connections
window.
.................................................................................................................................................................................................
17
Increase attenuation until a BER of 1x10
-10
is displayed on the SDH/SONET analyzer
for about two minutes.
.................................................................................................................................................................................................
18
Measure the optical power (= receiver sensitivity) at the output port of the optical
attenuator and enter the measured value in the table provided in chapter 9.
Important!
The optical power meter must be set to the appropriate wavelength
range (see
Table 8-2, “Receiver sensitivity” (p. 8-19)
.................................................................................................................................................................................................
19
Check that the measured value is within the range shown in
.................................................................................................................................................................................................
20
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Cross-Connection
→
Delete
to delete the established cross-connection.
Result: Screen 1
appears.
.................................................................................................................................................................................................
21
Click the
Equip
tab on the left.
Stand-alone test procedures
Receiver sensitivity test
.................................................................................................................................................................................................................................
8-18
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005