20
Select the existing
Path Protection
in the
Ptn Grp
tab on the left-hand side of the
window and click the
Select
button.
.................................................................................................................................................................................................
21
Check that “Working” is indicated as the
Active
path.
.................................................................................................................................................................................................
22
Click
Close
.
Deleting cross-connections
Proceed as follows to delete the established cross-connections:
.................................................................................................................................................................................................
1
Login to NE-A.
.................................................................................................................................................................................................
2
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Cross-Connection
→
Delete
to delete the established cross-connections.
Result: Screen 1
appears.
.................................................................................................................................................................................................
3
Click the
Equip
tab on the left.
.................................................................................................................................................................................................
4
Expand the tree of the circuit pack to which the analyzer is connected and select the
respective port.
Result:
In the list box on the right the existing cross-connection that shall be
deleted is displayed.
.................................................................................................................................................................................................
5
Select this cross-connection and click
Next>
.
Result: Screen 2
appears.
.................................................................................................................................................................................................
6
Select
ALL Legs
of this cross-connection and click
Next>
.
Network establishment and testing
SNCP/UPSR test
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
10-75
E
N D
O F
S
T E P S
.................................................................................................................................................................................................