Ring setup
Creating cross-connections
Proceed as follows to create the required cross-connections:
.................................................................................................................................................................................................
1
Connect the
WaveStar
®
CIT PC to NE-A and perform an NE login as described in
chapter 7, section
.................................................................................................................................................................................................
2
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Cross-Connection
→
Create
to set up a cross-connection.
Figure 10-10 SNCP/UPSR test setup
STM-x/OC-x
SDH/SONET
analyzer
NE-D
Tx
Rx
OP
Tx
Rx
OP
NE-C
OP
Rx Tx
OP
Rx
Tx
Fiber loop
1) Cross-connections
OP = Optical Pack
NE-A
OP
Rx Tx
1)
OP
Rx
Tx
Tx
Rx
OP
NE-B
1)
Tx
Rx
OP
Tx
Rx
OP
OP
Rx Tx
SNCP/UPSR
Working path
Protection path
Network establishment and testing
SNCP/UPSR test setup
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
10-45