Required equipment
Prior to performing this task, the following equipment must be available:
1.
WaveStar
®
CIT PC
2. CAT5 crossover LAN cable with RJ-45/RJ-45 connectors (see chapter 4,
4-48, “CIT connection (LAN crossed)” (p. 4-74)
3. SDH/SONET analyzer
The required transmission rate depends on the optical circuit packs used within the
ring. The optical circuit pack with the lowest transmission rate determines the
transmission rate which should be used for the test. For example, if OP2G5, OP10
and OP40 circuit packs are used, an STM-16/OC-48 transmission signal is required.
4. ESD Wrist Strap.
Prerequisites
Prior to performing this task, you must have done the following:
1. Established the fiber connections (see section
2. Configured the DCC channels of all used MS-SPRing/BLSR ports correctly (see
section
3. Logged in to
WaveStar
®
CIT as Super User (see chapter 5, section
) if
WaveStar
®
CIT User Login has been
enabled during
WaveStar
®
CIT installation.
Network establishment and testing
4-fiber MS-SPRing/BLSR test setup
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
10-37