Table 8-1
Mean launched power ranges
(continued)
Circuit pack
Comcode
Wavelength
[nm]
Mean launched power
range [dBm]
OP2G5/1.3SR4
109000265
1310
–10.0 ... –3.0
OP2G5/1.3LR4
109055657
1310
–2.0 ... +2.0
OP2G5/1.5LR4
109055665
1550
–2.0 ... +2.0
OM2G5/1.3SR1
(Module)
109192294
1310
–10.0 ... –3.0
OM2G5/1.3LR1
(Module)
109192286
1310
–2.0 ... +2.0
OM2G5/1.5LR1
(Module)
109192278
1550
–2.0 ... +2.0
OM2G5/921...959PWDM
(Modules)
109154658 ...
109154971
1550
–3.0 ... 0
OP622/1.3IR16
109091595
1310
–15.0 ... –8.0
OM622/1.3LR1
(Module)
109307017
1310
–3.0 ... +2.0
OM622/1.3IR1
(Module)
109307009
1310
–15.0 ... –8.0
OP155M/1.3IR16
109091603
1310
–15.0 ... –8.0
OM155/1.3LR1
(Module)
109306993
1310
–5.0 ... 0
OM155/1.3IR1
(Module)
109306977
1310
–15.0 ... –8.0
GE1/SX4
109000273
850
–9.5 ... –4.0
GE1/LX4
109192245
1310
–9.5 ... –3.0
Stand-alone test procedures
Optical power meter test
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
8-13