The cable consists of the parts listed in the table below.
Table 4-11
Connector/wire technical data (Single coax cable, STM-1e)
Part
Comcode
Connector:
1.6/5.6 coax (straight)
or
1.6/5.6 coax (45°)
408663482
.
Cable (without connector):
4.1 mm single coax with overall shield
or
4.1 mm 8 fold coax with overall shield
.
848068607 or 847716081
847716073
Multi coax cable
The multi coax cable (4.1 mm coax) has 8 straight or 45° 1.6/5.6 male connectors at
the subrack side and a blunt end at the DDF side. One cable contains 4 channels.
Protected STM-1e routing
Protected STM-1e cabling can be done with and without the use of a rack extension
(width). However, the use of a rack extension makes the cable routing much easier.
General information
The STM-1e cables need to be routed loosely (with some slack) to allow service
engineers to pull out an STM-1e interface paddle board without affecting traffic of an
adjacent interface.
Figure 4-24 Layout (Multi coax cable, STM-1e)
to DDF
Site specific length
17
ECI/155ME8 or
ECI/155MP8
18
1.6/5.6 male connectors
System cabling and final assembly
STM-1e interface
.................................................................................................................................................................................................................................