Test setup
Checking the external timing references
Proceed as follows to check the external timing references in NE-A:
.................................................................................................................................................................................................
1
Connect the
WaveStar
®
CIT PC to NE-A and perform an NE login as described in
chapter 7, section
.................................................................................................................................................................................................
2
In the
WaveStar
®
CIT
System View
, select
View
→
Timing/Sync...
.
Result:
The
Synchronization Characteristics
window appears.
.................................................................................................................................................................................................
3
Select the
External Reference 1
tab.
Figure 10-6 Line timing test setup
TI-A IN
TI-B IN
Tx
Rx
OP
Tx
Rx
OP
OP
Rx Tx
OP
Rx
Tx
OP
Rx
Tx
Tx
Rx
OP
OP
Rx Tx
Tx
Rx
OP
OP = Optical Pack
External clock
sources
NE-C
(Line timing)
NE-B
(Line timing)
NE-D
(Line timing)
NE-A
(External timing)
Network establishment and testing
Line timing test setup
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page