Result:
An additional tab labelled
ONNS
is displayed in the port provisioning
window.
Additional information
Port classes:
•
iNNI ports
interface to other iNNI ports and connect one ONNS node to
another ONNS node within an autonomous system. Furthermore, iNNI ports
must always be set to
adaptive
mode.
•
EDGE ports
delineate the boundary of a single ONNS routing domain; they
interface to nodes outside of the ONNS routing domain. EDGE ports do not
maintain ONNS signaling with each other. Furthermore, EDGE ports must
always be set to
fixed
mode.
.................................................................................................................................................................................................
5
Select the
ONNS
tab.
.................................................................................................................................................................................................
6
Select
Normal
in the
Port Control
drop-down list box.
.................................................................................................................................................................................................
7
Click
Apply
and confirm the resulting system message by clicking
Yes
.
.................................................................................................................................................................................................
8
Repeat
to
for all fiber cable ports that interconnect the ONNS NEs.
Important!
The
Port Class
must be set to
iNNI
and the
Tributary Mode
to
Adaptive-Rate
for all these ports.
.................................................................................................................................................................................................
9
Click
Close
to close the window.
.................................................................................................................................................................................................
10
Repeat
to
for all other NEs within the network.
Important!
The port to which “Analyzer 2” will be connected (NE-C) must be set
to
EDGE
, all other ports to
iNNI
.
E