Table 10-1
Power input ranges of the optical circuit packs
(continued)
Circuit pack
Comcode
Wavelength [nm]
Allowed range
[dBm]
OP2G5/921...959PWDM
(Modules)
109154658 ...
109154971
1550
–28.0 ... –8.0
OP622/1.3IR16
109091595
1310
–28.0 ... –8.0
OM622/1.3LR1
(Module)
109307017
1310
–28.0 ... –8.0
OM622/1.3IR1
(Module)
109307009
1310
–28.0 ... –8.0
OP155M/1.3IR16
109091603
1310
–28.0 ... –8.0
OM155/1.3LR1
(Module)
109306993
1310
–34.0 ... –10.0
OM155/1.3IR1
(Module)
109306977
1310
–28.0 ... –8.0
GE1/SX4
109000273
850
–17.0 ... 0.0
GE1/LX4
109192245
1310
–19.0 ... –3.0
Network establishment and testing
Connecting the fiber cables
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page