14
Before starting a signal transmission check that the optical output power of the
SDH/SONET analyzer is not too high. The allowed power input ranges for all optical
circuit packs are given in
Table 10-1, “Power input ranges of the optical circuit packs”
.................................................................................................................................................................................................
15
Start a signal transmission via the SDH/SONET analyzer for three minutes.
Result:
No bit errors are present during this time.
.................................................................................................................................................................................................
16
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Cross-Connection
→
Delete
to delete the established cross-connection.
Result: Screen 1
appears.
.................................................................................................................................................................................................
17
Click the
Equip
tab on the left.
.................................................................................................................................................................................................
18
Expand the tree of a circuit pack which contains cross-connections and select the
respective port.
Result:
In the list box on the right the AIDs of all sources and destinations of
cross-connections belonging to the respective port are displayed.
.................................................................................................................................................................................................
19
Select the cross-connection which shall be deleted and click
Next>
.
Result: Screen 2
appears.
.................................................................................................................................................................................................
20
Select
ALL Legs
of this cross-connection and click
Next>
.
Result: Screen 3
appears. This window contains the parameters of the selected
cross-connection.
.................................................................................................................................................................................................
21
Click
Finish>
to delete the cross-connection and confirm the resulting message by
clicking
Yes
.
.................................................................................................................................................................................................
22
Repeat
to
for all the other cross-connections that have been
established.
Stand-alone test procedures
Optical port transmission test (daisy chain test)
.................................................................................................................................................................................................................................
8-34
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005