Result:
The
Create New Protection Group
window appears.
.................................................................................................................................................................................................
3
Select the shelf in the
Ptn Grp
selection tab and click
Select I/O Shelf
.
Result:
On the right side of the window the protection parameter fields for the
selected shelf appear.
.................................................................................................................................................................................................
4
Select in the
Protection Type
drop-down list box the type
2-Fiber MS-SPRing
(SDH)
or
2-Fiber BLSR
(SONET).
Result:
The parameter fields for the MS-SPRing/BLSR appear.
.................................................................................................................................................................................................
5
Define the
Protection Group AID
by typing the last digit(s) in the respective text box.
This can be a maximum of three digits, a value from
1
to
999
is possible. Please note
that you have to choose different AIDs for different protection groups within one
network element. Within the whole ring identical Protection Group AIDs may exist.
.................................................................................................................................................................................................
6
Enter the
Ring ID
. The Ring ID is an alphanumeric string of up to 15 characters and
must be defined for the whole ring.
Important!
For all MS-SPRing/BLSR protection groups that are defined in network
elements belonging to one ring the same Ring ID always has to be entered.
.................................................................................................................................................................................................
7
Select the AIDs of
East Port
and
West Port
in the respective drop-down list boxes in
the
Group Member
group box. The values correspond to the slot designations.
.................................................................................................................................................................................................
8
The
Automatic Ring Discovery
should be
Enabled
to make sure that the NE will
search the adjacent NE automatically.
.................................................................................................................................................................................................
9
Set the
Wait to Restore
time in the drop-down list box to
5 Minutes
(Default).
.................................................................................................................................................................................................
10
All other parameters in the window shall remain on the default values and not been
changed.
.................................................................................................................................................................................................
11
Verify that all parameters are correct. Click
Apply
and then
Yes
in the confirmation
window.
Network establishment and testing
2-fiber MS-SPRing/BLSR test setup
.................................................................................................................................................................................................................................
10-32
Lucent Technologies - Proprietary
See notice on first page
365-374-187