1+1 protection test
.................................................................................................................................................................................................................................
Purpose
This test provides a scenario for testing the ONNS 1+1 protection.
Creation of paths
Two paths must be created for a 1+1 protection. Proceed as follows to create the first
path between NE-A, NE-D and NE-C, and the second (protection) path between NE-A,
NE-D, NE-B and NE-C:
.................................................................................................................................................................................................
1
Select
Configuration
→
Create New Path
from the map’s menu bar.
Result:
A
Create New Path
screen appears, requesting you to provide information.
.................................................................................................................................................................................................
2
Select the signal rate (bandwidth) which shall be used via the
Signal Rate
drop-down
list box.
Important!
Make sure that the EDGE ports to which the analyzers are connected
are configured to the same signal rate as the analyzers!
.................................................................................................................................................................................................
3
Select in the
Source
group box via the
Node IP
drop-down list box the SCN IP
address of NE-A (see section
“Setting the IP address and ONNS system parameters of
.................................................................................................................................................................................................
4
Select in the
Source
group box via the
Port
drop-down list box the port to which
“analyzer 1” is connected.
.................................................................................................................................................................................................
5
Select in the
Source
group box via the
Trib
drop-down list box the desired tributary.
.................................................................................................................................................................................................
6
Select in the
Destination
group box via the
Node IP
drop-down list box the SCN IP
address of NE-C (see section
“Setting the IP address and ONNS system parameters of
.................................................................................................................................................................................................
7
Select in the
Destination
group box via the
Port
drop-down list box the port to which
“analyzer 2” is connected.