Path creation test
.................................................................................................................................................................................................................................
Purpose
This test provides a procedure for testing the automatic connection setup via ONNS.
Procedure
Proceed as follows to create a path between NE-A and NE-C via NE-B and NE-D:
.................................................................................................................................................................................................
1
Connect an SDH/SONET analyzer (= “Analyzer 1”) to an optical port of NE-A that
has been configured for ONNS (see section
“Optical port provisioning for SCN”
Important!
Clarify that the optical input signal is in the correct optical power input
range (see section
Table 10-1, “Power input ranges of the optical circuit packs”
.................................................................................................................................................................................................
2
Log in to the
WaveStar
®
CIT as Super User (see chapter 5, section
.................................................................................................................................................................................................
3
In the
WaveStar
®
CIT
NE Management View
, select
View
→
ONNS View
.
.................................................................................................................................................................................................
4
In the
WaveStar
®
CIT
NE Management View
, select
File
→
Discover Network
.
.................................................................................................................................................................................................
5
Select
Configuration
→
Create New Path
from the map’s menu bar.
Result:
A
Create New Path
screen appears, requesting you to provide information.
.................................................................................................................................................................................................
6
Select the signal rate (bandwidth) which shall be used via the
Signal Rate
drop-down
list box.
Important!
Make sure that the EDGE ports to which the analyzers are connected
are configured to the same signal rate as the analyzers!
.................................................................................................................................................................................................
7
Select in the
Source
group box via the
Node IP
drop-down list box the SCN IP
address of NE-A (see section
“Setting the IP address and ONNS system parameters of
Network establishment and testing
.................................................................................................................................................................................................................................