9
In the
Fault Management
group box, specify the Alarm Severity Assignment Profile
(ASAP) for unprotected equipment (ASAP type “Equipment unprotected”) by means of
the
Equipment Alarm Severity Assignment Profile
drop-down list box.
.................................................................................................................................................................................................
10
In the
Fault Management
group box, specify the Alarm Severity Assignment Profile
(ASAP) relating to the Data Communication Network (ASAP type “Data
Communications Network”) by means of the
DCN Alarm Severity Assignment
Profile
drop-down list box.
.................................................................................................................................................................................................
11
Click
Apply
and confirm the resulting system message by clicking
Yes
.
.................................................................................................................................................................................................
12
Click
Close
to exit the
Provision Parameters for Protection Group or Equipment
window.
.................................................................................................................................................................................................
13
IF
{
THEN
{
TCP/IP access is required,
skip the following steps and proceed with section
“LAN port configuration for TCP/IP access”
(p. 7-22)
TCP/IP access is not required,
proceed with
.................................................................................................................................................................................................
14
In the
WaveStar
®
CIT
System View
, select
Fault
→
Enter/Exit Maintenance
Condition...
→
Exit Maintenance Condition...
.
Result:
The
LambdaUnite
®
MSS NE will now perform a system reset (takes about
ten minutes). As a consequence, the management association between the
WaveStar
®
CIT and the NE will be lost.
After
the boot process the following must be observed:
•
The “Active” LEDs on all circuit packs are permanently illuminated with the
exception of the XC protection pack in slot “XC P” (#10). No LED is
illuminated on this circuit pack.
•
Only the “ABN” LED on the User Panel is illuminated.
This is because the system timing is not yet provisioned (see section
Troubleshooting:
If the “Fault” LED is flashing on one or more circuit packs or if
circuit pack alarms are displayed in the
WaveStar
®
CIT alarm list, refer to appendix
A, section
“Circuit pack alarm handling” (p. A-12)
NE provisioning
System parameters
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
7-19