7
Mount the front mounting brackets (with mounted fiber clips) loosely on the subrack
using M4x8 screws (DC1002976, item 7).
.................................................................................................................................................................................................
8
Mount the subrack on the front rack frame using M6x16 screws (CC901331421, item
4) with 7 ± 1.0 Nm [61.96 ± 2.65 lbs-in] torque. Use the following hole positions:
#32, #37, #42, #48, #54, #59 and #64 (see section
.................................................................................................................................................................................................
9
Tighten the M4x8 screws (DC1002976, item 7) completely.
.................................................................................................................................................................................................
10
Mount one DC1001517 fiber guide (item 8) on the bottom right side of the subrack
and one DC1001516 fiber guide (item 9) on the bottom left side of the subrack using
two self-tapping screws.
.................................................................................................................................................................................................
11
Mount one DC1001517 fiber guide (item 8) on the top left side of the subrack and one
DC1001516 fiber guide (item 9) on the top right side of the subrack using two M2.5
self-tapping screws.
.................................................................................................................................................................................................
12
Mount one side guide (DC1001518, item 3) at each corner of the subrack by clicking
them into the holes at the top and bottom sides of the subrack.
Mixed configuration:
LambdaUnite
®
MSS and
Metropolis
®
DMX (High Capacity)
Mounting the
LambdaUnite
®
MSS subrack
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
E-3