Result:
The
Synchronization Characteristics
window appears.
.................................................................................................................................................................................................
3
Check that the following parameters are set for both external clock sources as given in
the table below. If necessary change the parameters according to section
(chapter 7).
Tab / Parameter
Value
External Input 1/2 tab
Input Signal Format
according to the format of the external
clock source
SSM Support
see section
(chapter 7)
External Reference 1/2 tab
Provisioned Quality Level
“PRC” (SDH) or “PRS” (SONET)
System Timing Reference Priority
“1” (External Reference 1)
“2” (External Reference 2)
Assigned Port AID
External Timing Input Port 1/2
Timing Port Mode Monitoring
Monitored
System Timing tab
Wait To Restore
1 minute
Clock Mode
Locked
.................................................................................................................................................................................................
4
Verify that the NE is synchronizing onto the first clock source for at least three
minutes. To do this, select
View
→
Timing/Sync
, then the
System Timing
tab.
Result: “External Timing Input Port 1”
should be displayed in the
System
Timing Reference AID
field.
.................................................................................................................................................................................................
5
Select the
System Timing
tab.
Result:
The following should be displayed:
•
“Normal”
in the
Clock mode Status
field
•
“Locked”
in the
Clock Mode
field
•
“PRC”
(SDH) or
“PRS”
(SONET) in the
System Quality Level Status
field.
.................................................................................................................................................................................................
6
Disconnect the first clock source.
Stand-alone test procedures
NE synchronization test
.................................................................................................................................................................................................................................
8-8
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005