Launching the
WaveStar
®
CIT ONNS application for the first
time
.................................................................................................................................................................................................................................
Purpose
This section provides a procedure for launching the
WaveStar
®
CIT ONNS application
for the first time.
Required equipment
Prior to performing this task, the following equipment must be available:
1.
WaveStar
®
CIT PC
2. CAT5 crossover LAN cable with RJ-45/RJ-45 connectors (see chapter 4,
4-48, “CIT connection (LAN crossed)” (p. 4-74)
Procedure
Proceed as follows to launch the
WaveStar
®
CIT ONNS application for the first time:
.................................................................................................................................................................................................
1
Log in to the
WaveStar
®
CIT as Super User (see chapter 5, section
Result:
The
WaveStar
®
CIT will update information from the connected NEs. This
will take a few minutes and is displayed in the
Network View
of the
WaveStar
®
CIT.
.................................................................................................................................................................................................
2
In the
WaveStar
®
CIT
NE Management View
, select
View
→
ONNS View
.
.................................................................................................................................................................................................
3
In the
WaveStar
®
CIT
NE Management View
, select
File
→
Discover Network
.
Result:
A couple of windows appear successively indicating that the IP addresses
cannot be found in the configuation file. After confirming these messages an
Edit
Configuration
screen appears.
.................................................................................................................................................................................................
4
In the
Edit Configuration
screen you have to modify the entries for all the displayed
entries representing ONNS nodes:
•
Leave the
SIG-IP
fields unchanged.
•
In all
UI-IP
fields enter the IP address of the
WaveStar
®
CIT or “127.0.0.1” (OSI).
.................................................................................................................................................................................................
5
If necessary edit the
Alias
field.
Network establishment and testing
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
10-87