Complete the following steps to mount a NEBS-2000 rack on the floor:
.................................................................................................................................................................................................
1
Drill the necessary holes (18 mm [0.7”] in diameter and 100 mm [4”] in depth) in the
floor using the drilling template (SC1006025, item 4).
Important!
Read the label for drilling instructions!
.................................................................................................................................................................................................
2
Put the rack frame in place.
.................................................................................................................................................................................................
3
Put the appropriate earthquake anchor (CC408414951 or CC408526242, item 2)
through the anchor hole provided in the rack bottom plate.
.................................................................................................................................................................................................
4
Place the required number of shim plates (SC1006075, item 3) around the anchor to
balance the rack frame in a horizontal position.
.................................................................................................................................................................................................
5
Push or tap the anchor until the plate washer is flat against the rack frame.
.................................................................................................................................................................................................
6
Tighten the bottom plate of the rack (item 1) to the floor using the nut of the anchor.
Figure 3-22 Drilling template (NEBS-2000 rack)
Mechanical installation
Floor mounting
.................................................................................................................................................................................................................................
3-42
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005