Path restoration test
.................................................................................................................................................................................................................................
Purpose
This test provides a procedure for testing the automatic path restoration function of
ONNS.
Procedure
Proceed as follows to perform the test:
.................................................................................................................................................................................................
1
Remove the fiber connection between NE-C and NE-D.
Result:
The existing path between NE-A, NE-B, NE-D and NE-C disappears after
a few seconds. However, a new path between NE-A, NE-B and NE-C will be
generated automatically (highlighted in green).
.................................................................................................................................................................................................
2
Check that no bit errors are present.
E
N D
O F
S
T E P S
........................................................................................................................................................................................................................
Network establishment and testing
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
10-97