Result:
The current data of the cross-connection are displayed.
.................................................................................................................................................................................................
11
Select
NORM
as
Output Mode
in the
Source to Destination
and
Destination to
Source
group boxes.
.................................................................................................................................................................................................
12
Type a 9-digit number for the cross-connection in the
XC Number
field or use the
automatically generated one.
.................................................................................................................................................................................................
13
Click the
Apply
button to apply your settings and confirm the resulting message by
clicking
Yes
.
.................................................................................................................................................................................................
14
Click
Close
to exit the
Create New Cross Connection
window.
.................................................................................................................................................................................................
15
Verify that the cross-connection is established. Proceed as follows:
1. In the
WaveStar
®
CIT
System View
, select
View
→
Cross-Connections...
2. Select
Shelf 1 (DUR)
of the
Ptn Grp
tab
3. Click
Select
and confirm the resulting message by clicking
Yes
.
.................................................................................................................................................................................................
16
Click
Close
to exit the
View Cross Connections
window.
.................................................................................................................................................................................................
17
Start a signal transmission via the transmission analyzer for one minute. Use 44.736
Mbit/s as signal rate.
NOTE:
The default DS3 signal format is “C-bit parity”. If you want to change this,
please refer to chapter 4 of the “
LambdaUnite
®
MSS User Operations Guide”.
Result:
No bit errors are present during this time.
.................................................................................................................................................................................................
18
Create a signal error and verify the result with the transmission analyzer.
.................................................................................................................................................................................................
19
IF ...
THEN ...
further DS3 ports must be tested
or
a DS3 protection test shall not be
performed,
proceed to
Stand-alone test procedures
DS3 transmission and protection test
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
8-25