22
Expand the tree of the circuit pack to which the SDH/SONET analyzer is connected
and select the respective port.
Result:
In the list box on the right the existing cross-connection that shall be
deleted is displayed.
.................................................................................................................................................................................................
23
Select this cross-connection and click
Next>
.
Result: Screen 2
appears.
.................................................................................................................................................................................................
24
Select
ALL Legs
of this cross-connection and click
Next>
.
Result: Screen 3
appears. This window contains the parameters of the selected
cross-connection.
.................................................................................................................................................................................................
25
Click
Finish>
to delete the cross-connection and confirm the resulting message by
clicking
Yes
.
.................................................................................................................................................................................................
26
Click
Close
to exit the
Delete Cross Connection
window.
.................................................................................................................................................................................................
27
Repeat
to
for all optical ports.
Value ranges
The following table provides the receiver sensitivity value and wavelength ranges of
the optical circuit packs.
Table 8-2
Receiver sensitivity
Circuit pack
Comcode
Wavelength [nm]
Receiver
sensitivity [dBm]
OP40/1.3IOR1
109055640
1310
≤
–5.0
OP40/1.5LR1O
109000174
1550
≤
–14.0
OP40/9280...8650XT
109055772 ...
109056499
1550
≤
–10.5
OP10/1.3IOR1
109000216
1310
≤
–11.0
OP10/1.5IR1
109077073
1550
≤
–14.0
Stand-alone test procedures
Receiver sensitivity test
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
8-19