Procedure
Important!
Only ports to which fiber cables are connected should be configured
for DCC terminations!
Proceed as follows to create a new DCC termination:
.................................................................................................................................................................................................
1
Connect the
WaveStar
®
CIT PC to NE-A and perform an NE login as described in
chapter 7, section
.................................................................................................................................................................................................
2
In the
WaveStar
®
CIT
System View
, select
Configuration
→
DCC Terminations...
.
Result:
The
Configure DCC Terminations
window appears. The
Equip
selection
tab appears on the left side of the window.
.................................................................................................................................................................................................
3
Select the circuit pack for which you want to configure the DCC terminations in the
Equip
selection tab and click
Select
.
Result:
The
Section DCC
tab appears on the right side.
.................................................................................................................................................................................................
4
IF ...
THEN ...
Section DCC
shall be provisioned,
proceed to Step 5.
Line DCC
shall be provisioned,
click the
Line DCC
tab.
.................................................................................................................................................................................................
5
Click
Select port for new DCC termination...
and select the optical interface port for
which you want to configure the DCC terminations.
.................................................................................................................................................................................................
6
In the
DCC Channel Parameters
group box, enable the
DCC termination
by
selecting the
Enabled
option.
.................................................................................................................................................................................................
7
In the
DCC Channel Parameters
group box, select the
LAPD Role
.
Important!
The chosen parameters have to be different at both ends of the DCC
termination if the DCCs are terminating on other equipment than
LambdaUnite
®
MSS. That means, one end must be set to
USER-SIDE
, and the other end to
NETWORK-SIDE
.
Network establishment and testing
Provision DCC
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
10-13