System timing
.................................................................................................................................................................................................................................
Overview
This section provides a procedure for configuring the system timing.
Required equipment
Prior to performing this task, the following equipment must be available:
1.
WaveStar
®
CIT PC
2. CAT5 crossover LAN cable with RJ-45/RJ-45 connectors (see chapter 4,
4-48, “CIT connection (LAN crossed)” (p. 4-74)
Prerequisites
Prior to performing this task, you must have done the following:
1. Logged in to
WaveStar
®
CIT as Super User (see chapter 5, section
) if
WaveStar
®
CIT User Login has been
enabled during
WaveStar
®
CIT installation.
2. Logged in to the NE.
Procedure
Complete the following steps to configure the system timing:
.................................................................................................................................................................................................
1
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Timing/Sync
.
Result:
The
Synchronization Characteristics
window appears.
.................................................................................................................................................................................................
2
Select the
System Timing
tab, then the appearing
System Timing
tab.
.................................................................................................................................................................................................
3
Select the wait-to-restore time in the
Wait To Restore
group box (see
). Click one of the following radio buttons:
•
0 Seconds
•
Minutes
The number of minutes has to be selected via a spin box (value range:
1 ... 60
in
one-minute steps)
•
Infinite
(SONET mode only).
.................................................................................................................................................................................................
4
Enable or disable the use of
System Synchronization Status Messaging Mode
by
selecting
QL Enable
or
QL Disable
.
NE provisioning
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
7-39