
Result:
In the
Tributary
list box on the right, the AIDs of all VCs/STSs belonging
to the respective port are displayed.
.................................................................................................................................................................................................
6
Select the VC/STS which shall be used as the source and click the
Select
button.
.................................................................................................................................................................................................
7
Select the destination port which is the interface to the MS-SPRing/BLSR in the
Ptn
Grp
selection tab and the corresponding VC/STS in the
Tributary
list box.
.................................................................................................................................................................................................
8
Click the
Select
button.
Result:
The current data of the cross-connection are displayed. The
Source NE
Name
is grayed out.
.................................................................................................................................................................................................
9
Select
NE-B
as the
Destination NE Name
.
.................................................................................................................................................................................................
10
Click the
Apply
button to apply your settings.
.................................................................................................................................................................................................
11
Repeat
to
for NE-B.
Note the following differences:
•
As
Source
select the port which is the interface to the MS-SPRing/BLSR.
•
As
Destination
select the port to which the fiber loop is connected.
•
Select
NE-A
as the
Source NE Name
.
Reference
The 4-fiber MS-SPRing/BLSR test is described in section
Network establishment and testing
4-fiber MS-SPRing/BLSR test setup
.................................................................................................................................................................................................................................
10-42
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
E
N D
O F
S
T E P S
.................................................................................................................................................................................................