4
Check that the following is fulfilled:
•
The
Assigned Port AID
displays
External Timing Input Port 1
.
•
The
Provisioned Quality Level
is set to
PRC
(SDH) or
PRS
(SONET).
•
The
Timing Port Mode Monitoring
is set to
Monitored
.
.................................................................................................................................................................................................
5
IF ...
THEN ...
the settings correspond to
proceed to
the settings do not correspond to
click
Close
and change the parameters via
Configuration
→
Timing/Sync
(see chapter 7,
section
“External timing references” (p. 7-36)
.................................................................................................................................................................................................
6
In the
WaveStar
®
CIT
System View
, select
View
→
Timing/Sync...
.
Result:
The
Synchronization Characteristics
window appears.
.................................................................................................................................................................................................
7
Select the
External Reference 2
tab.
.................................................................................................................................................................................................
8
Check that the following is fulfilled:
•
The
Assigned Port AID
displays
External Timing Input Port 2
.
•
The
Provisioned Quality Level
is set to
PRC
(SDH) or
PRS
(SONET).
•
The
Timing Port Mode Monitoring
is set to
Monitored
.
.................................................................................................................................................................................................
9
IF ...
THEN ...
the settings correspond to
Click
Close
.
the settings do not correspond to
click
Close
and change the parameters via
Configuration
→
Timing/Sync
(see chapter 7,
section
“External timing references” (p. 7-36)
Network establishment and testing
Line timing test setup
.................................................................................................................................................................................................................................
10-20
Lucent Technologies - Proprietary
See notice on first page
365-374-187
Issue 1, December 2005
E
N D
O F
S
T E P S
.................................................................................................................................................................................................