4
In the
XC Application
group box, select
2-Way Point-to-Point
.
.................................................................................................................................................................................................
5
Click the left
Select
button to select the source tributary.
Result:
The
Ptn Grp
selection tab appears.
.................................................................................................................................................................................................
6
Select the port to which the SDH/SONET analyzer is connected.
Result:
In the
Tributary
list box on the right, the AIDs of all VCs/STSs belonging
to the respective port are displayed.
.................................................................................................................................................................................................
7
Select the VC/STS which shall be used as the source and click the
Select
button.
.................................................................................................................................................................................................
8
Select the destination port (= port with optical fiber loop) and the corresponding
VC/STS in the
Tributary
list box.
.................................................................................................................................................................................................
9
Click the
Select
button.
Result:
The current data of the cross-connection are displayed.
.................................................................................................................................................................................................
10
Select
NORM
as
Output Mode
in the
Source to Destination
and
Destination to
Source
group boxes.
.................................................................................................................................................................................................
11
Type a 9-digit number for the cross-connection in the
XC Number
field or use the
automatically generated one.
.................................................................................................................................................................................................
12
Click the
Apply
button to apply your settings and confirm the resulting message by
clicking
Yes
.
.................................................................................................................................................................................................
13
Click
Close
to exit the
Create New Cross Connection
window.
.................................................................................................................................................................................................
14
Verify that the cross-connection is established. Proceed as follows:
1. In the
WaveStar
®
CIT
System View
, select
View
→
Cross-Connections...
2. Select
Shelf 1 (DUR)
of the
Ptn Grp
tab
3. Click
Select
and confirm the resulting message by clicking
Yes
.
Stand-alone test procedures
XC and CTL protection test
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
8-39