4. Only the XC320/B variants of the XC320 cross-connect and timing units support
ONNS applications.
5. It is recommended to use
two
XC320 cross-connect and timing units. Thus, both
the cross-connnect as well as the timing function are automatically 1+1 equipment
protected. However, an LXC configuration with a single, but unprotected XC320
cross-connect and timing unit is also possible.
LXC640 configuration rules
These rules and guidelines apply when the
Maximum Switch Capacity
of the system
is set to
LXC640
(640 Gbit/s):
1. The maximum switching capacity of the system is 640 Gbit/s (12288 × 12288
VC-3/STS-1; 4096 × 4096 VC4).
2. Port units can be used in
all
universal slots, and
all
universal slots can be used.
That is also valid for port units with a transmission capacity of 20 Gbit/s (e.g.
OP2G5D and OP10D circuit packs).
3. Only XC640 cross-connect and timing units can be provisioned in slot 9 and
slot 10.
If any cross-connect and timing unit other than an XC640 is installed in slot 9 or
slot 10, the green activity LED of that cross-connect and timing unit will flash, and
a “Circuit Pack Type Mismatch” alarm will be reported.
Figure 5-13 LXC configuration rules with XC320
21
40
12
32
23
25
27
User panel
front view
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
CTL (P) slot
Univ
ersal slot
CTL (W) slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
Univ
ersal slot
XC (W) slot
XC (P) slot
Univ
ersal slot
Univ
ersal slot
22
Univ
ersal slot
24
Univ
ersal slot
26
Univ
ersal slot
28
Univ
ersal slot
1
2
3
5
6
7
8
13 14 15 16
18
33 34 35 36
38
Univ
ersal slot
37
Univ
ersal slot
17
Univ
ersal slot
39
Univ
ersal slot
19
9
10 11
31
Univ
ersal slot
4
Power, software and circuit pack installation
Configuration rules
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
5-47