Key combination
Function
Tab
Access next input field, next checkbox or next button.
Ctrl + Tab
Access previous input field, previous checkbox or previous button.
Space bar
Activate or deactivate activated checkboxes.
Actuate activated buttons.
Parameter panels
Ctrl + F6
Switch between graphical and tabular display.
Additional information
è
Parameter panels (tabular display)
Ctrl + L
Show/hide all of the filters
è
Ctrl + F
Switch to search field in title bar of the working area
è
Enter
Switch from the search back to the parameter panel.
Tab
Access next column header.
If the last column header has been accessed, it switches to the currently
selected list element. It switches from the currently selected list element to
the first column header.
Shift + tab
Access previous column header.
If the first column header has been accessed, it switches to the currently
selected list element. It switches from the currently selected list element to
the last column header.
Arrow keys
Navigate within the table.
Pop-up (to edit components and events)
Tab
Access next input field, next list, next checkbox or next button.
Arrow keys
Navigate within an accessed list.
Enter
If available, press key to complete processing.
Esc
Close pop-up.
Tab. 8 Description of the key combinations for the plug-in
2.1.5
Basic and user units
The plug-in provides the option to select specific user units. The following units are supported and
applied to the corresponding values:
–
Internal increments [Inci, Inci/s, …]
–
Increments [Inc, Inc/s, …]
–
Rev [rev, rps, …]
–
Rev [rev, rpm, …]
–
Rad [rad, rad/s, …]
–
Degree [°, °/s, …]
CMMT-ST Plug-in
22
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW