ID Px.
Parameters
Description
7166
Current switch-off
delay holding brake
Unit
s
Switch-on delay saved in the EEPROM for the execution of a
command if an electronic data sheet for the Festo motor is
stored.
Access
read/−
Update
reinitialization
7161
Switch-on delay hold-
ing brake
Unit
s
The delay saved in the EEPROM for the deactivation of the regu-
lator if an electronic data sheet for the Festo motor is stored.
Access
read/−
Update
reinitialization
7164
Switch-off delay hold-
ing brake
Unit
s
Activation of the current reduction for the holding brake
Access
read/write
Update
effective immediately
40001
Activation current
reduction holding
brake
Unit
−
Specifies the time with which the current reduction for the hold-
ing brake is initiated.
Access
read/write
Update
effective immediately
40002
Delay time
Unit
s
Specifies the voltage supplied to the holding brake before cur-
rent reduction is initiated. The voltage is only output if the cur-
rent reduction for the holding brake is activated (Px.4001.0.0)
Access
read/write
Update
effective immediately
40003
Supply voltage hold-
ing brake
Unit
V
Specifies the voltage to which it is reduced after elapse of the
delay time.
Access
read/write
Update
effective immediately
40004
Holding voltage
Unit
V
Tab. 118 Parameters
Product configuration
151
Festo — CMMT-ST-SW — 2019-02