ID Px.
Parameters
Description
Shows the tolerance time for the STA feedback signal.
Access
read/−
Update
effective immediately
952
STA hysteresis time
Unit
s
Tab. 409 Parameters
ID Dx.
Name
Description
09 | 00 | 00146
(150995090)
Safety function requested
Safety function requested
09 | 00 | 00147
(150995091)
Plausibility check of safety feed-
back signals
Error during plausibility check of safety feed-
back signals
09 | 01 | 00148
(151060628)
STO: Discrepancy time exceeded
Discrepancy time for #STO-A/B exceeded
09 | 01 | 00149
(151060629)
Plausibility check #STO-A/B
Plausibility check of #STO-A/B input
09 | 01 | 00150
(151060630)
Sequence monitoring #STO-A/B
Sequence monitoring, #STO-A/B inputs
Tab. 410 Diagnostic messages
8.2
CiA402
Objects
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved base unit for the object is effective.
950
0x2178.1
SFB error status
UINT32
951
0x2178.2
Feedback signals
UINT32
952
0x2178.3
STA hysteresis time
FLOAT32
Tab. 411 Objects
9
Diagnostics and fault clearance
9.1
Diagnostics options
The servo drive provides comprehensive diagnostics options.
The status LEDs of the device display the current status information.
The web server and the plug-in of the Festo Automation Suite provide access to diagnostic messages
in plain text format.
Fieldbus-specific diagnostic functions are available via the fieldbus.
Diagnostics and fault clearance
430
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW