ID Dx.
Message
Description
Default: save (1)
18 | 00 | 00227
(301990115)
Encoder identification
reports incorrect
encoder type
Error
memory
Can be parameterised: No
Common error quadrature encoder
Remedy
–
Check encoder cable
–
Restart device
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
18 | 03 | 00235
(302186731)
Incremental encoder
analysis invalid
Error
memory
Can be parameterised: No
Incorrect zero pulse or incorrect number of increments per
revolution
Remedy
–
Check encoder cable
–
Check encoder
Default: Warning (16)
Classifica-
tion
Can be parameterised: Px.10061, value list:
Stop category 0 (4096)
Stop category 1 (256)
Stop category 2 (64)
Warning (16)
Info (4)
Ignore (2)
Default: save (1)
18 | 03 | 00301
(302186797)
Number of increments
between two zero
pulses invalid
Error
memory
Can be parameterised: Px.10060
Check the wiring of the encoder and the position resolu-
tion of the BiSS-C protocol.
Remedy
–
Check encoder cable
–
Restart device
Default: Stop category 0 (4096)
Classifica-
tion
Can be parameterised: No
Default: save (1)
18 | 05 | 00239
(302317807)
BiSS-C encoder ana-
lysis invalid
Error
memory
Can be parameterised: No
Tab. 428 Diagnostic messages
Diagnostics and fault clearance
497
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......