Parameters
Index.Subindex
Name
Data type
14111
0x2184.08
Mileage error threshold
SINT64
Tab. 445 Objects
9.6.2
Load change counter
The load change counter records how many backlashes the drive completes. The unwanted recording
of small positioning differences is suppressed by a hysteresis function (random noise). Two threshold
values can be specified per parameterisation. A diagnostic message is issued if they are exceeded.
The reaction of the servo drive when the threshold value is exceeded can be influenced by specifying
the error category.
Parameters and diagnostic messages
ID Px.
Parameters
Description
Specifies the current number of load changes for the corres-
ponding axis.
Access
read/write
Update
effective immediately
1421
Load change counter
Unit
−
Specifies the first threshold value when the device should gen-
erate the first configured message.
Access
read/write
Update
effective immediately
1427
Warning threshold
load change counter
Unit
−
Specifies the second threshold value when the device should
generate the second configured message.
Access
read/write
Update
effective immediately
14211
Error threshold load
change counter
Unit
−
Tab. 446 Parameters
ID Dx.
Name
Description
12 | 01 | 00211
(201392339)
Maximum load change value
reached
The maximum value for the load change is
reached
12 | 01 | 00212
(201392340)
Load change warning threshold
reached
Threshold value 1 (default: warning
threshold) for the load change is reached
Diagnostics and fault clearance