Subindex
Name
Data type
Access
PDO map-
ping
Parameter
0x21A1.09
Variable message function
status
BOOL
ro
Tx
P0.1174210.0.0
0x21A1.0A
Current axis ID data trigger
UINT16
ro
Tx
P0.1174211.0.0
0x21A1.0B
Current data ID data trigger UINT32
ro
Tx
P0.1174212.0.0
0x21A1.0C
Current data instance ID
data trigger
UINT16
ro
Tx
P0.1174213.0.0
0x21A1.0D
Current array ID data trig-
ger
UINT16
ro
Tx
P0.1174214.0.0
0x21A1.0E
Current trigger level
SINT64
ro
Tx
P0.1174215.0.0
0x21A1.0F
Current hysteresis of trig-
ger level
SINT64
ro
Tx
P0.1174216.0.0
0x21A1.10
Current data trigger damp-
ing time
FLOAT32
ro
Tx
P0.1174217.0.0
0x21A1.11
Data trigger status
BOOL
ro
Tx
P0.1174220.0.0
0x21A2.01
Resolution single turn
UINT32
rw
Rx
P0.3601.0.0
0x21A2.02
Resolution multiturn
UINT32
rw
Rx
P0.3602.0.0
0x21A2.03
Single-turn position
UINT32
ro
Tx
P0.3603.0.0
0x21A2.04
Multi-turn numerator
UINT32
ro
Tx
P0.3604.0.0
0x21A2.0A
CRC BiSS-C
UINT8
ro
Tx
P0.3610.0.0
0x21A2.0C
Baud rate
UINT32
rw
Rx
P0.3612.0.0
0x21A2.0D
Activation of correction
table
BOOL
rw
Rx
P0.3613.0.0
0x21A2.0E
Activation read out exten-
ded encoder data
BOOL
rw
Rx
P0.3618.0.0
0x21A2.14
Encoder serial number
STRING(20)
rw
Rx
P0.3624.0.0 ... 19
0x21A4.01
Web server activation
BOOL
rw
Rx
P0.11280051.0.0
0x21A5.01
Scaling factor start value
I²t monitoring motor model
FLOAT32
rw
Rx
P1.6301.0.0
0x21A5.02
Actual value I²T monitoring
motor model
FLOAT32
ro
Tx
P1.6302.0.0
0x21A5.03
Maximum start value I²t
monitoring motor model
FLOAT32
ro
Tx
P1.6303.0.0
EtherCAT