ID Px.
Parameters
Description
Determines the numerator of the user-defined feed constant
(data type UINT32).
Index 0: gear ratio group 1
Index 1: gear ratio group 2
Access
read/write
Update
reinitialization
11593
Numerator feed con-
stant (user defined)
Unit
−
Determines the denominator of the user-defined feed constant
(data type UINT32).
Index 0: gear ratio group 1
Index 1: gear ratio group 2
Access
read/write
Update
reinitialization
11594
Denominator feed
constant (user
defined)
Unit
−
Tab. 145 Parameters of gear ratio groups 1 and 2
Parameter from the drive configuration
If a drive configuration was performed using the plug-in, the parameters named in the following table
are assumed from the drive configuration. The plug-in calculates the numerator from parameters
Px.1232, Px.1233, Px.1236, Px.1237, Px.1240 and Px.1241 and the denominator of the overall trans-
mission ratio of the gear ratio group 0 (Px.1242 and Px.1243).
For the closed-loop controller, the gear ratio of the selected gear ratio group is relevant
è
If the gear ratio group 0 is selected, parameters Px.1242 and Px.1243 calculated by the plug-in can be
changed as required. The change has no influence on the abovementioned parameters from the drive
configuration (Px.1232, Px.1233, etc.).
ID Px.
Parameters
Description
Specifies the database ID of the first gear unit.
Access
read/write
Update
effective immediately
1230
Database ID gear unit
1
Unit
−
Specifies the order code of the first configured gear unit.
Access
read/write
Update
effective immediately
1231
NOC code gear unit 1
Unit
−
Product configuration
175
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW