Bit
1)
Description
13
12
Drive follows the command value (Drive follows the command value)
x
0
Drive does not follow the command value for internal reasons (e. g. because a
safety function is active)
x
1
Drive in operation enabled status and follows the command value.
Position following error (Following error)
0
1
Position following error in tolerance range
1
1
Position following error limit reached
1) Signal status: 0 = low; 1 = high
Tab. 208 Monitoring cyclic synchronised positioning mode (CSP)
4.1.7
Cyclic synchronised velocity mode (CSV)
4.1.7.1
Function
The cyclic synchronised velocity mode enables command values to be pre-set for the device in a fixed
time grid using the drive profile (SYNC interval). The import of the command values is synchronised
with the synchronisation signal of the higher-order controller. The synchronisation signal is generally
slower by a whole number than the cycle of the closed-loop controller. The synchronisation time is
generally set by the higher-order PLC (synchronisation time 1 … 20 ms, step 1 ms,
è
Px.1051). The
integrated fine interpolator therefore calculates intermediate support points and derivations from the
setpoint quantity for the closed-loop controller (interpolation).
Monitoring functions
The monitoring functions marked with a dot are effective in this operating mode:
Motion monitoring function status word
Bit
Code
Name
effective
0
TRX
Target window reaches position
–
1
TRV
Target window reaches velocity
–
2
TRT
Target window reaches torque
–
3
FEX
Following error position
–
4
FEV
Velocity following error
·
6
TMX
Position target area monitoring
–
7
TMV
Speed target area monitoring
–
8
TMT
Torque target area monitoring
–
9…11
–
Reserved
–
12
HLP
Hardware limit switch reached positive
·
Motion control
233
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......