ID Px.
Parameters
Description
Specifies the resulting maximum torque for torque limitation.
Access
read/−
Update
effective immediately
6105
Resulting upper limit
value torque (closed
loop controller)
Unit
−
Specifies the limit value "Lower limit value of the active cur-
rent". (Conversion to the output-side torque is an internal calcu-
lation)
Access
read/−
Update
effective immediately
6108
Resulting lower limit
value active current
(closed loop control-
ler)
Unit
Arms
Specifies the limit value "Upper limit value of the active cur-
rent". (Conversion to the output-side torque is an internal calcu-
lation)
Access
read/−
Update
effective immediately
6109
Resulting upper limit
value active current
(closed loop control-
ler)
Unit
Arms
Specifies the limit value of the total current.
Access
read/−
Update
effective immediately
6112
Resulting upper limit
value total current
(closed loop control-
ler)
Unit
Arms
Tab. 370 Parameters
Diagnostic messages
No specific diagnostic messages are allocated to the function.
6.2.3.1
CiA 402
Torque limitation objects
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
87
0x2153.08
Reactive current setpoint value
FLOAT32
856
0x2168.07
Limit value total current (closed loop control-
ler)
FLOAT32
2218
0x215B.0A
Minimum torque
FLOAT32
2219
0x215B.0B
Maximum torque
FLOAT32
Control
371
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......