ID Px.
Parameters
Description
Touch probe status CiA402
Access
read/−
Update
effective immediately
113033
Touch probe status
CiA402
Unit
−
Hysteresis for the modulo position for secure detection during a
modulo run
Access
read/write
Update
effective immediately
113034
Modulo hysteresis
Unit
user defined
Specifies the currently used hysteresis for the modulo position
for secure detection during a modulo run.
Access
read/−
Update
effective immediately
113035
Current modulo hys-
teresis
Unit
user defined
Specifies the delay time during which the digital input signal is
delayed
Access
read/write
Update
effective immediately
113036
Delay time
Unit
s
Specifies the currently used delay time during which the digital
input signal is delayed
Access
read/−
Update
effective immediately
113037
Current delay time
Unit
s
Tab. 397 Parameters
Parameters of the touch probe mode (Px.113000 and Px.113007)
Value
Mode
Description
0
inactive
The position detection is inactive.
1
Once
One-time position detection without limiting the trig-
ger range; after the measurement has been performed,
the function is deactivated automatically.
Technology functions
417
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......