ID Px.
Parameters
Description
112707
Switching time
(manual)
Unit
s
Determines the direction of movement at which the cam switch
shall activate.
–
0: Negative/positive direction
–
1: Positive direction
–
2: Negative direction
Depending on the product design, several cams can be paramet-
erised within the defined modulo range.
Index 0: cam switch 1
Index 1: cam switch 2
Index 2: (depending on the product design)
Index 3: ...
Access
read/write
Update
effective immediately
112708
Selection of switching
function
Unit
−
Determines the switching behaviour of the cam switch. For the
On to Off switching function, the switching points are specified
in the parameters Px.112710 and Px.112711. The time for the
time-controlled switching behaviour is specified via parameter
Px.112712.
–
0: Inactive
–
1: Cam switch On/Off
–
2: Cam switch ON, time-controlled
–
3: Cam switch OFF, time-controlled
Depending on the product design, several cams can be paramet-
erised within the defined modulo range.
Index 0: cam switch 1
Index 1: cam switch 2
Index 2: (depending on the product design)
Index 3: ...
Access
read/write
Update
effective immediately
112709
Selection of switching
characteristics
Unit
−
112710
First switching point
Defines the first switching point at which the cam switch should
be active.
Index 0: cam switch 1
Index 1: cam switch 2