ID Px.
Parameters
Description
Specifies the value of the second comparator type-dependent
parameter
è
Record step enabling type parameter (ID Px.1831)
Access
read/write
Update
effective immediately
1836
Record sequencing
field 2
Unit
−
Shows the current record number.
Access
read/−
Update
effective immediately
1837
Current record table
index
Unit
−
Tab. 264 Parameters
The record enabling depends on the configured monitoring windows with a comparator that depends
on a motion monitor.
Record step enabling type parameter (ID Px.1831)
Value
Record enabling types The step enabling condition is
achieved when ...
comparator type-dependent
parameters
0
no comparator
– (comparator not specified)
– (none)
1
Target position
reached
... the motion monitor reports
that the target position has
been reached.
– (none)
2
Target velocity
reached
... the motion monitor reports
that the target velocity has been
reached.
– (none)
3
Target torque reached ... the motion monitor reports
that the target torque has been
reached.
– (none)
4
Digital input
... the digital input checks the
parameterised level (high or low
level).
The requested input must be
configured as input for use in
1.
Input:
–
11: record table input
0
–
12: record table input
1
Motion control
290