ID Px.
Parameters
Description
Specifies the limit value "Lower limit value of the active cur-
rent". (Conversion to the output-side torque is an internal calcu-
lation)
Access
read/−
Update
effective immediately
6108
Resulting lower limit
value active current
(closed loop control-
ler)
Unit
Arms
Specifies the limit value "Upper limit value of the active cur-
rent". (Conversion to the output-side torque is an internal calcu-
lation)
Access
read/−
Update
effective immediately
6109
Resulting upper limit
value active current
(closed loop control-
ler)
Unit
Arms
Tab. 366 Parameters
ID Dx.
Name
Description
06 | 02 | 00087
(100794455)
Velocity control limitation invalid
Velocity control limitation invalid
06 | 02 | 00088
(100794456)
Torque control limitation invalid
Torque control limitation invalid
06 | 02 | 00089
(100794457)
Current control limitation invalid
Current control limitation invalid
06 | 02 | 00090
(100794458)
Maximum peak current control
limitation invalid
Maximum peak current control limitation
invalid
Tab. 367 Diagnostic messages
6.2.2.1
CiA 402
Control limitation objects
Parameters
Index.Subindex
Name
Data type
Px.
CiA402: factor group is effective.
852
0x60E1.00
Lower limit value torque (closed loop control-
ler)
UINT16
853
0x60E0.00
Upper limit value torque (closed loop control-
ler)
UINT16
Control
367
Festo — CMMT-ST-SW — 2019-02