Defining the axis zero point
If the axis zero point is selected in the interactive graphic, it is displayed in blue and can be moved.
The distance between the axis zero point and the reference point is set in the "Software limits"para-
meter group.
When moving the axis zero point, the scale is moved at the same time.
The values of the software limit positions remain the same. The displayed positions of the software
limit positions are moved.
The reference point value is modified. The displayed position of the reference point remains the same.
The axis zero point value can also be specified in the "Software limits"parameter group and is then
adjusted in the interactive graphic.
Defining software limit positions
If the software limit positions are selected in the interactive graphic, they are displayed in blue and
can be moved. The values of the software limit positions are adjusted in the "Software limits"para-
meter group.
When the software limit positions are moved, the effective stroke is calculated, and the corresponding
text field is updated in the graphic.
The values of the software limit positions can also be specified in the "Software limits"parameter
group and are then updated in the interactive graphic.
Defining the reference point
The standard value of the reference point is 0.0 if a referencing method with a negative direction is
selected.
If a referencing method with a positive direction is selected, the reference point is at the point of the
set working stroke. The scale is depicted in a negative way.
If the reference point is selected in the interactive graphic, it is displayed in blue and can be moved.
When moving the reference point, the scale is moved at the same time.
The values of the software limit positions and axis zero point remain the same. The displayed posi-
tions of the software limit positions and axis zero point are moved.
2.3
Parameterisation
2.3.1
Interface
Toolbar
In addition to the standard commands, the toolbar for the "Parameterisation" context also contains
the following commands:
Designation
Function
"Load factory settings"
Load factory parameter record for the device.
The command can be executed if the following prerequisites are met:
–
The plug-in is connected to a device.
CMMT-ST Plug-in
46
Festo — CMMT-ST-SW — 2019-02