ID Px.
Parameters
Description
Activates the current reduction after detection of standstill
Access
read/write
Update
effective immediately
4026
Current reduction
activation
Unit
−
Specifies the delay time with which current reduction is effective
after reaching standstill detection.
Access
read/write
Update
effective immediately
4027
Current reduction
delay time
Unit
s
Specifies the scaling factor for current reduction based on the
nominal current
Access
read/write
Update
effective immediately
4028
Current reduction
scaling factor
Unit
−
Defines the factor for the current setpoint used for the commut-
ation angle determination.
Access
read/write
Update
effective immediately
6694
Factor current set-
point value
Unit
−
Tab. 403 Parameters
ID Dx.
Name
Description
06 | 02 | 00273
(100794641)
Change of control structure not
permissible
The change of the control structure is not per-
missible
06 | 02 | 00274
(100794642)
Motion command not permissible
The motion command is not permissible in
controlled operation
06 | 02 | 00275
(100794643)
Change to closed loop operation
not permissible
Change to closed loop operation not permiss-
ible because the commutation angle is not
valid
Tab. 404 Diagnostic messages