Operating mode parameters with controller enable (Px.10234)
Value
Operating mode
Description
15
Start record table
On issue of controller enable the record table is activ-
ated. The device reacts as follows:
–
stop category 2
è
9.2 Classification of diagnostic events.
–
After elapse of the switch-on delay the paramet-
erised record is automatically run (Px.10238).
Tab. 224 Possible operating modes with controller enable via I/O
4.1.9.2
CiA 402
Objects
Parameters
Index.Subindex
Name
Data type
Px.
Manufacturer-specific objects: saved basic unit for the object is effective.
10231
0x218E.01
Device status
UINT32
10232
0x218E.02
Controller enable selection
UINT32
10234
0x218E.03
Controller enable operating mode
UINT32
10235
0x218E.04
Target velocity for controller enable (velocity
operation)
FLOAT32
10236
0x218E.05
Target torque for controller enable (torque
operation)
FLOAT32
10237
0x218E.06
Maximum velocity for controller enable
(torque operation)
FLOAT32
10238
0x218E.07
Index for controller enable
SINT32
11280018
0x218E.08
Torque increase for controller enable
FLOAT32
Tab. 225 Objects
4.2
Stop
4.2.1
Function
The stop command aborts the current motion command. The subsequent reactions to the stop com-
mand depend on what triggered the stop.
Motion control