Parameters
Index.Subindex
Name
Data type
71500
0x2130.93
Actual acceleration value unfiltered
FLOAT32
71501
0x2130.95
Actual acceleration value filtered
FLOAT32
71502
0x2130.97
Filter time constant acceleration filter
FLOAT32
Tab. 127 Objects
3.3.3.4
Parameters of digital incremental encoders (A, B and N signals)
ID Px.
Parameters
Description
Specifies the number of increments per Encoder revolution.
Parameter P0.10040.0.0 for the encoder at encoder interface 1
and parameter P0.10040.1.0 for the encoder at encoder inter-
face 2 (device specific).
Access
read/write
Update
reinitialization
10040
Encoder resolution
Unit
Inc/r
Specifies the raw position value delivered by the single-turn
encoder in increments.
Access
read/−
Update
effective immediately
10041
Raw value position
Unit
−
Specifies the raw value of the number of revolutions determined
by the single-turn encoder.
Access
read/−
Update
effective immediately
10042
Raw value number of
revolutions
Unit
−
Determines how the quadrature signal of the encoder shall be
evaluated.
This means:
–
1: single evaluation
–
2: double evaluation
–
4: quadruple evaluation
Access
read/write
Update
reinitialization
10043
Quadrature evalu-
ation
Unit
−
Product configuration
162
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......