![Festo CMMT-ST-SW Скачать руководство пользователя страница 554](http://html1.mh-extra.com/html/festo/cmmt-st-sw/cmmt-st-sw_original-instructions-manual_2283377554.webp)
Index.
Subindex
Name
Data type
Access
PDO map-
ping
Parameter
0x60D2.00
Time stamp touch probe
position negative CiA402
UINT32
ro
Tx
P1.113028.0.0
0x60D5.00
Counter initiated trigger
events positive edge
CiA402
UINT16
ro
Tx
P1.113031.0.0
0x60D6.00
Counter initiated trigger
events negative edge
CiA402
UINT16
ro
Tx
P1.113032.0.0
0x60BA.00
Touch probe position posit-
ive CiA402
SINT32
ro
Tx
P1.113029.0.0
0x60BB.00
Touch probe position neg-
ative CiA402
SINT32
ro
Tx
P1.113030.0.0
0x60D3.00
Time stamp touch probe
position positive CiA402
UINT32
ro
Tx
P1.113027.1.0
0x60D4.00
Time stamp touch probe
position negative CiA402
UINT32
ro
Tx
P1.113028.1.0
0x60D7.00
Counter initiated trigger
events positive edge
CiA402
UINT16
ro
Tx
P1.113031.1.0
0x60D8.00
Counter initiated trigger
events negative edge
CiA402
UINT16
ro
Tx
P1.113032.1.0
0x60BC.00
Touch probe position posit-
ive CiA402
SINT32
ro
Tx
P1.113029.1.0
0x60BD.00
Touch probe position neg-
ative CiA402
SINT32
ro
Tx
P1.113030.1.0
Manufacturer-specific objects: the base unit saved for the object is effective.
0x2100.01
Activate keep-alive-signal
BOOL
rw
Rx
P0.12008.0.0
0x2100.02
Keep-alive-signal wait time UINT32
rw
Rx
P0.12009.0.0
0x2100.03
Keep-alive-signal repeat
time
UINT32
rw
Rx
P0.12010.0.0
0x2100.04
Maximum number of repe-
titions
UINT32
rw
Rx
P0.12011.0.0
0x2103.01
Order number
UINT32
ro
Tx
P0.70.0.0
0x2103.02
NOC code
STRING(50)
ro
Tx
P0.71.0.0 ... 49